Production Switcher · Production Gallery
PCR-SW-01
Monitored Functions Healthy
SimulatedUpdated 10 sec ago
Switcher
Online
On air
Programme
Active
On air
Preview
Not Monitored
Source Input
Present
SDI-RTR-01 locked
Reference
Locked
FAC-SYNC-01 locked
Programme Output
Not Monitored
Active Incident
Production graphics election data stale
The Production Graphics renderer remains healthy, but its required election data value 47.3% is stale against the configured 30s freshness threshold.
Data / Metadata Assurance
Election Graphics Data
Data trust, freshness, provenance, rights, fallback, and output evidence are assessed separately from renderer and system health.
STALE
Freshness
Primary election result: 47.3% is stale; last confirmed 4m 18s ago against 30s threshold.
Provenance
ELECTION-DATA-01 (licensed_provider); observed; canonical state canonical.
Verification
unverified; confidence 0.92.
Fallback
Fallback not configured.
Output Impact
Required operational data is at risk, but confirmed output impact is unknown without final output/as-run evidence.
Related systems
ELECTION-DATA-01, GRAPHICS-DATA-ADAPTER-01, GRAPHICS-CONTROL-01, VIZ-ENGINE-01, PCR-SW-01
Canonical value
47.3% · canonical
Evidence gaps
Current data state is stale; it must not be presented as current or healthy.; Rights or entitlement status is unknown and must not be treated as allowed.; No fallback source is configured for this data flow.
Engineering Details
Coverage, monitoring points, metrics, inventory, connections, collectors, and provenance
8/12 points
Engineering Details
Coverage, monitoring points, metrics, inventory, connections, collectors, and provenance
Monitoring Coverage
One evidence boundary for available and missing monitoring points.
Available8
Not Collected4
Recent Events1
Connections5
View monitoring points and gaps
Available · 8
Current System SignalsProgramme bus, Source input, Graphics input
Production SwitcherProgramme bus, Source input, Graphics input, Output, Reference
Not Collected · 4
Required Production Switcher CollectorsProgramme / preview bus state, Input and output alarm feed, Control and automation event stream, Output signal probe
Monitoring Layers
Host
N/A
Operating System
N/A
Application
N/A
Media
Simulated · 0 gaps
Data / Metadata
N/A
Network
Simulated · 4 gaps
Storage
N/A
Detailed Metrics
Media1 groups · 0 gaps
Media
1 groups · 0 gaps
Current System Signals
Current normalized values used for the system's observed state.
Programme busSimulated
On air
Source inputSimulated
SDI-RTR-01 locked
Graphics inputSimulated
VIZ-ENGINE-01 configured
Network2 groups · 4 gaps
Network
2 groups · 4 gaps
Production Switcher
Programme-bus, source, graphics, and reference indicators for the representative PCR stage.
Programme busSimulated
On air
Source inputSimulated
SDI-RTR-01 locked
Graphics inputSimulated
VIZ-ENGINE-01 configured
OutputSimulated
MCR-PLAYOUT-01
ReferenceSimulated
FAC-SYNC-01 locked
Required Production Switcher Collectors
Live switcher state requires device APIs, tally/state events, alarms, and output monitoring.
Programme / preview bus stateNot collected
Collector not configured
Input and output alarm feedNot collected
Collector not configured
Control and automation event streamNot collected
Collector not configured
Output signal probeNot collected
Collector not configured